Your Shopping Cart
Collection: Products
-
Vendor:Hager
Hager Brass Busbar Terminal 2P | 90A
Architecture Number of poles 2 P Dimensions Product installed depth 44 mm Product height installed 86 mm Product width installed 129 mm Materials Weight of the brass contained in the product 130 g Transparent No Accessories included Closure plate required NoRegular price Rs 1,425.00Regular priceUnit price / per -
Vendor:Hager
Hager Brass Busbar Terminal 4P
Architecture Number of poles 4 P Dimensions Product installed depth 44 | 44 | 60 mm Product height installed 86 | 86 | 86 mm Product width installed 88| 129 | 162 mm Materials Weight of the brass contained in the product Transparent No Accessories included Closure plate required NoRegular price Rs 1,020.00Regular priceUnit price / per -
Vendor:Hager
Hager Change Over Switch 2P | 63A
Technical characteristics Architecture Number of poles 2 P Main electrical features Rated operational voltage Ue 230 V Frequency 50;60 Hz Rated current 63 A Voltage Rated insulation voltage 500 V Rated impulse withstand voltage 4000 V Dimensions Depth of installed product 72 mm Height of installed product 90 mm Width of installed product 71.5 mm Power Total power loss under IN 3.6 W Endurance Number...Regular price Rs 3,440.00Regular priceUnit price / per -
Vendor:Hager
Hager Change Over Switch 4P | 63A
Technical characteristics Architecture Number of poles 2 P Main electrical features Rated operational voltage Ue 230 V Frequency 50;60 Hz Rated current 63 A Voltage Rated insulation voltage 500 V Rated impulse withstand voltage 4000 V Dimensions Depth of installed product 72 mm Height of installed product 90 mm Width of installed product 71.5 mm Power Total power loss under IN 3.6 W Endurance Number...Regular price Rs 7,330.00Regular priceUnit price / per -
Vendor:Hager
Hager Circuit Breaker / Disjoncteur (C Curve) 1P+N - 10A
Hager Circuit Breaker / Disjoncteur (C Curve) 1P+N - 10A Architecture Neutral position left Number of poles 2 P Type of pole 1P+N Curve C Main electrical features Rated operational voltage Ue 230 / 240 V Frequency 50;60 Hz Type of supply voltage AC Voltage Rated insulation voltage 500 V Max operating voltage 253 V Rated impulse withstand voltage 4000 V Electric current Rated...Regular price Rs 420.00Regular priceUnit price / per -
Vendor:Hager
Hager Circuit Breaker / Disjoncteur (C Curve) 1P+N - 16A
Hager Circuit Breaker / Disjoncteur (C Curve) 1P+N - 16A Architecture Neutral position left Number of poles 2 P Type of pole 1P+N Curve C Main electrical features Rated operational voltage Ue 230 / 240 V Frequency 50;60 Hz Type of supply voltage AC Voltage Rated insulation voltage 500 V Max operating voltage 253 V Rated impulse withstand voltage 4000 V Electric current Rated...Regular price Rs 420.00Regular priceUnit price / per -
Vendor:Hager
Hager Circuit Breaker / Disjoncteur (C Curve) 1P+N - 20A
Hager Circuit Breaker / Disjoncteur (C Curve) 1P+N - 20A Architecture Neutral position left Number of poles 2 P Type of pole 1P+N Curve C Main electrical features Rated operational voltage Ue 230 / 240 V Frequency 50;60 Hz Type of supply voltage AC Voltage Rated insulation voltage 500 V Max operating voltage 253 V Rated impulse withstand voltage 4000 V Electric current Rated...Regular price Rs 420.00Regular priceUnit price / per -
Vendor:Hager
Hager Circuit Breaker / Disjoncteur (C Curve) 1P+N - 25A
Hager Circuit Breaker / Disjoncteur (C Curve) 1P+N - 25A Architecture Neutral position left Number of poles 2 P Type of pole 1P+N Curve C Main electrical features Rated operational voltage Ue 230 / 240 V Frequency 50;60 Hz Type of supply voltage AC Voltage Rated insulation voltage 500 V Max operating voltage 253 V Rated impulse withstand voltage 4000 V Electric current Rated...Regular price Rs 420.00Regular priceUnit price / per -
Vendor:Hager
Hager Circuit Breaker / Disjoncteur (C Curve) 1P+N - 32A
Hager Circuit Breaker / Disjoncteur (C Curve) 1P+N - 32A Architecture Neutral position left Number of poles 2 P Type of pole 1P+N Curve C Main electrical features Rated operational voltage Ue 230 / 240 V Frequency 50;60 Hz Type of supply voltage AC Voltage Rated insulation voltage 500 V Max operating voltage 253 V Rated impulse withstand voltage 4000 V Electric current Rated...Regular price Rs 420.00Regular priceUnit price / per -
Vendor:Hager
Hager Circuit Breaker / Disjoncteur (C Curve) 1P+N - 40A
Hager Circuit Breaker / Disjoncteur (C Curve) 1P+N - 40A Architecture Neutral position left Number of poles 2 P Type of pole 1P+N Curve C Main electrical features Rated operational voltage Ue 230 / 240 V Frequency 50;60 Hz Type of supply voltage AC Voltage Rated insulation voltage 500 V Max operating voltage 253 V Rated impulse withstand voltage 4000 V Electric current Rated...Regular price Rs 465.00Regular priceUnit price / per -
Vendor:Hager
Hager Circuit Breaker / Disjoncteur (C Curve) 2P - 10A
Hager Circuit Breaker / Disjoncteur (C Curve) 2P - 10A Architecture Neutral position without neutral Number of poles 2 P Type of pole 2 P Fixing mode Din-Rail Curve C Main electrical features Rated operational voltage Ue 400 V Type of supply voltage AC Voltage Rated insulation voltage 500 V Rated impulse withstand voltage 6000 V Electric current Rated service breaking capacity Ics...Regular price Rs 900.00Regular priceUnit price / per -
Vendor:Hager
Hager Circuit Breaker / Disjoncteur (C Curve) 2P - 16A
Hager Circuit Breaker / Disjoncteur (C Curve) 2P - 16A Architecture Neutral position without neutral Number of poles 2 P Type of pole 2 P Fixing mode Din-Rail Curve C Main electrical features Rated operational voltage Ue 400 V Type of supply voltage AC Voltage Rated insulation voltage 500 V Rated impulse withstand voltage 6000 V Electric current Rated service breaking capacity Ics AC...Regular price Rs 900.00Regular priceUnit price / per -
Vendor:Hager
Hager Circuit Breaker / Disjoncteur (C Curve) 2P - 20A
Hager Circuit Breaker / Disjoncteur (C Curve) 2P - 20A Architecture Neutral position without neutral Number of poles 2 P Type of pole 2 P Fixing mode Din-Rail Curve C Main electrical features Rated operational voltage Ue 400 V Type of supply voltage AC Voltage Rated insulation voltage 500 V Rated impulse withstand voltage 6000 V Electric current Rated service breaking capacity Ics AC...Regular price Rs 900.00Regular priceUnit price / per -
Vendor:Hager
Hager Circuit Breaker / Disjoncteur (C Curve) 2P - 25A
Hager Circuit Breaker / Disjoncteur (C Curve) 2P - 25A Architecture Neutral position without neutral Number of poles 2 P Type of pole 2 P Fixing mode Din-Rail Curve C Main electrical features Rated operational voltage Ue 400 V Type of supply voltage AC Voltage Rated insulation voltage 500 V Rated impulse withstand voltage 6000 V Electric current Rated service breaking capacity Ics AC...Regular price Rs 900.00Regular priceUnit price / per -
Vendor:Hager
Hager Circuit Breaker / Disjoncteur (C Curve) 2P - 32A
Hager Circuit Breaker / Disjoncteur (C Curve) 2P - 32A Architecture Neutral position without neutral Number of poles 2 P Type of pole 2 P Fixing mode Din-Rail Curve C Main electrical features Rated operational voltage Ue 400 V Type of supply voltage AC Voltage Rated insulation voltage 500 V Rated impulse withstand voltage 6000 V Electric current Rated service breaking capacity Ics AC...Regular price Rs 900.00Regular priceUnit price / per -
Vendor:Hager
Hager Circuit Breaker / Disjoncteur (C Curve) 2P - 40A
Hager Circuit Breaker / Disjoncteur (C Curve) 2P - 40A Architecture Neutral position without neutral Number of poles 2 P Type of pole 2 P Fixing mode Din-Rail Curve C Main electrical features Rated operational voltage Ue 400 V Type of supply voltage AC Voltage Rated insulation voltage 500 V Rated impulse withstand voltage 6000 V Electric current Rated service breaking capacity Ics AC...Regular price Rs 900.00Regular priceUnit price / per -
Vendor:Hager
Hager Circuit Breaker / Disjoncteur (C Curve) 2P - 50A
Hager Circuit Breaker / Disjoncteur (C Curve) 2P - 50A Architecture Neutral position without neutral Number of poles 2 P Type of pole 2 P Fixing mode Din-Rail Curve C Main electrical features Rated operational voltage Ue 400 V Type of supply voltage AC Voltage Rated insulation voltage 500 V Rated impulse withstand voltage 6000 V Electric current Rated service breaking capacity Ics AC...Regular price Rs 945.00Regular priceUnit price / per -
Vendor:Hager
Hager Circuit Breaker / Disjoncteur (C Curve) 2P - 63A
Hager Circuit Breaker / Disjoncteur (C Curve) 2P - 63A Architecture Neutral position without neutral Number of poles 2 P Type of pole 2 P Fixing mode Din-Rail Curve C Main electrical features Rated operational voltage Ue 400 V Type of supply voltage AC Voltage Rated insulation voltage 500 V Rated impulse withstand voltage 6000 V Electric current Rated service breaking capacity Ics AC...Regular price Rs 975.00Regular priceUnit price / per -
Vendor:Hager
Hager Circuit Breaker / Disjoncteur (C Curve) 4P - 100A
Hager Circuit Breaker / Disjoncteur (C Curve) 4P - 100A - 6 Modules Architecture Neutral position without neutral Number of poles 4 P Type of pole 4 P Fixing mode Din-Rail Curve C Main electrical features Rated operational voltage Ue 400 V Type of supply voltage AC Voltage Rated insulation voltage 500 V Rated impulse withstand voltage 6000 V Electric current Rated service breaking...Regular price Rs 10,765.00Regular priceUnit price / per -
Vendor:Hager
Hager Circuit Breaker / Disjoncteur (C Curve) 4P - 10A
Hager Circuit Breaker / Disjoncteur (C Curve) 4P - 10A Architecture Neutral position without neutral Number of poles 4 P Type of pole 4 P Fixing mode Din-Rail Curve C Main electrical features Rated operational voltage Ue 400 V Type of supply voltage AC Voltage Rated insulation voltage 500 V Rated impulse withstand voltage 6000 V Electric current Rated service breaking capacity Ics AC...Regular price Rs 1,645.00Regular priceUnit price / per -
Vendor:Hager
Hager Circuit Breaker / Disjoncteur (C Curve) 4P - 125A
Hager Circuit Breaker / Disjoncteur (C Curve) 4P - 125A - 6 Modules Architecture Neutral position without neutral Number of poles 4 P Type of pole 4 P Fixing mode Din-Rail Curve C Main electrical features Rated operational voltage Ue 400 V Type of supply voltage AC Voltage Rated insulation voltage 500 V Rated impulse withstand voltage 6000 V Electric current Rated service breaking...Regular price Rs 15,400.00Regular priceUnit price / per -
Vendor:Hager
Hager Circuit Breaker / Disjoncteur (C Curve) 4P - 16A
Hager Circuit Breaker / Disjoncteur (C Curve) 4P - 16A Architecture Neutral position without neutral Number of poles 4 P Type of pole 4 P Fixing mode Din-Rail Curve C Main electrical features Rated operational voltage Ue 400 V Type of supply voltage AC Voltage Rated insulation voltage 500 V Rated impulse withstand voltage 6000 V Electric current Rated service breaking capacity Ics AC...Regular price Rs 1,645.00Regular priceUnit price / per -
Vendor:Hager
Hager Circuit Breaker / Disjoncteur (C Curve) 4P - 20A
Hager Circuit Breaker / Disjoncteur (C Curve) 4P - 20A Architecture Neutral position without neutral Number of poles 4 P Type of pole 4 P Fixing mode Din-Rail Curve C Main electrical features Rated operational voltage Ue 400 V Type of supply voltage AC Voltage Rated insulation voltage 500 V Rated impulse withstand voltage 6000 V Electric current Rated service breaking capacity Ics...Regular price Rs 1,645.00Regular priceUnit price / per -
Vendor:Hager
Hager Circuit Breaker / Disjoncteur (C Curve) 4P - 25A
Hager Circuit Breaker / Disjoncteur (C Curve) 4P - 25A Architecture Neutral position without neutral Number of poles 4 P Type of pole 4 P Fixing mode Din-Rail Curve C Main electrical features Rated operational voltage Ue 400 V Type of supply voltage AC Voltage Rated insulation voltage 500 V Rated impulse withstand voltage 6000 V Electric current Rated service breaking capacity Ics...Regular price Rs 1,645.00Regular priceUnit price / per -
Vendor:Hager
Hager Circuit Breaker / Disjoncteur (C Curve) 4P - 32A
Hager Circuit Breaker / Disjoncteur (C Curve) 4P - 32A Architecture Neutral position without neutral Number of poles 4 P Type of pole 4 P Fixing mode Din-Rail Curve C Main electrical features Rated operational voltage Ue 400 V Type of supply voltage AC Voltage Rated insulation voltage 500 V Rated impulse withstand voltage 6000 V Electric current Rated service breaking capacity Ics AC...Regular price Rs 1,645.00Regular priceUnit price / per -
Vendor:Hager
Hager Circuit Breaker / Disjoncteur (C Curve) 4P - 40A
Hager Circuit Breaker / Disjoncteur (C Curve) 4P - 40A Architecture Neutral position without neutral Number of poles 4 P Type of pole 4 P Fixing mode Din-Rail Curve C Main electrical features Rated operational voltage Ue 400 V Type of supply voltage AC Voltage Rated insulation voltage 500 V Rated impulse withstand voltage 6000 V Electric current Rated service breaking capacity Ics AC...Regular price Rs 2,095.00Regular priceUnit price / per -
Vendor:Hager
Hager Circuit Breaker / Disjoncteur (C Curve) 4P - 50A
Hager Circuit Breaker / Disjoncteur (C Curve) 4P - 50A Architecture Neutral position without neutral Number of poles 4 P Type of pole 4 P Fixing mode Din-Rail Curve C Main electrical features Rated operational voltage Ue 400 V Type of supply voltage AC Voltage Rated insulation voltage 500 V Rated impulse withstand voltage 6000 V Electric current Rated service breaking capacity Ics AC...Regular price Rs 2,845.00Regular priceUnit price / per -
Vendor:Hager
Hager Circuit Breaker / Disjoncteur (C Curve) 4P - 63A
Hager Circuit Breaker / Disjoncteur (C Curve) 4P - 63A Architecture Neutral position without neutral Number of poles 4 P Type of pole 4 P Fixing mode Din-Rail Curve C Main electrical features Rated operational voltage Ue 400 V Type of supply voltage AC Voltage Rated insulation voltage 500 V Rated impulse withstand voltage 6000 V Electric current Rated service breaking capacity Ics AC...Regular price Rs 2,990.00Regular priceUnit price / per